Designed and
manufactured by Magus Electronics using the
latest
microprocessor technology, the Vibrosound
Analyser ("Vibrosound") meets the
requirements of all Vibration and Noise
(leq) monitoring and is continually updated
in line with legislative changes.
Supplied as a Noise only, Vibration only or a unique Simultaneous Sound
and Vibration monitor; the Vibrosound
CM-2 is housed in
a sealed IP65 case for operation in harsh
environmental conditions, with the 3 event
timer providing automatic, unattended
monitoring.
The PC Link option provides storage of
events before subsequent transfer to a
compatible PC. User-friendly PC software is
included for data analysis to BS6472,
DIN4150 and USBM/OSMRE standards.
The Vibrosound is compatible with PCMCIA
Type 2 Cards for additional flexibility,
including 20Mb Flash Cards for increased
event storage capacity.
The
Site Compliance Monitor CM2
and the Quarry Blast Monitor QB1 have many
common features as given below. The
differences between them are for the Site
Compliance Monitor :-
Vibrosound Analyser for Vibration Only or
Noise (leq) Only or Simultaneous
monitoring. for the Quarry
Blast Monitor :- Vibrosound
Analyser with Vibration and linear Air Over
Pressure with noise (LEQ) option.
Common Features
Vibration 3 or 6 channels: single or
triaxial, acceleration, displacement,
velocity, frequency, resultant peak particle
velocity using 0.5hz accelerometer.
Linear air overpressure.
Noise (leq) option type 1 precision
grade noise analyser.
Leqs: overall max 5 min, hourly leq +5 min,
L10, L30, L50, L90, Lmax, user definable
period for leq, 5 min leq, L10, L30, L50,
L90, other percentiles optional.
Data tabulated to user defined intervals.
Three modes of operation: impulse,
continuous or dual mode, incorporating
3 event timer
Battery/mains power operated, incorporating
internal battery charger
VDV and DIN filter options.
MODES
AUTOMATIC TRIGGER (IMPULSE) MODE:
Triggers on any vibration
exceeding the user defined trigger
value. Used for blast
monitoring or similar events. Event
length user-selectable.
CONTINUOUS MODE
Used to record Peak Vibration
and Noise Leq (in dB(A) or
(C)) over extended periods. Manual
or automatic operation
using 3-event timer, repeated
daily. Data tabulated at user
defined intervals. Ideal for Noise
surveys and monitoring of
general construction operations to
ensure compliance with project
limits. Applications include:
Piling, Railways, Highways, Bridges etc.
DUAL MODE
Continuous monitoring for
Vibration and Air Overpressure,
with vibration exceeding the
trigger value producing an
impulse event. Each impulse event
is printed as it occurs,
with the continuous event printed
at the end of the monitoring period.
Real Time Calendar/Clock for
Date/Time print-out with results and 3 event
timer per day for unattended operation of
several weeks.
LCD Display of 4 lines by 20 characters
and full QWERTY keyboard.
Internal Printer/Plotter, 4 colour for
superimposed graphs on plain or graph paper,
complete with Take-up Spool and
cover.
User-friendly software - Reprinting
Event; 1 Min Pause; Quantity of full results
printed before returning to Block Print-out
when left unattended. Separate or combined
graphs, user
selectable.
Battery/Mains operated incorporating
internal battery charger. Battery life:
Typically 5 days; High capacity option
typically 15 days.
Computer Interface (RS232) and P.C.
Software if required.
Strong Case sealed to IP65, Weight:
10.5Kg.